FTPC217×系列 光敏晶体管输出型光耦合器 V3.06 (1.27SOP-4L贴片 红外LED+光敏晶体管 VISO≥3750Vrms 7种CTR分档 A/B/C/D/L/L1/S 80-600% UL/cUL E178703 + VDE 40004708 + CQC CQC23001413664 + RoHS + REACH -55~+110°C 数字逻辑+电源控制+电路隔离) | F-tone Networks 北亿纤通FTPC217系列 光敏晶体管输出型光耦合器, 光无源器件, 光耦继电器, 布线与配线管理-10, -10 to +70°C, -10 to 80C SFP, -10dBm, -14.4dBm, -20dBm Sensitivity, -25dBm LOSD, -31dBm, -3dBm Overload, -3dBm Saturation, -40到80度, (2011/65/EU), (Halogen, (Lead, (LV)TTL Input/Output, (LV)TTL Logic, (Optional), (Pulsed), (TYP), < 6mA Power, +15V, +260°C, +3.3V, +3.3V Power Supply, ±2kV, ±40nm Bandwidth, ≤0.5μm, ≤2.0dB, ★ Key Control Dimension, 0.0025 公差, 0.7mm Guide Pin, 0.8 nm Spacing, 0.85W Max, 0~70°C工作温度, 1.0-8.9N Peak, 1.25 Gbps Data Rate, 1.25G Router, 1.25G SFP 8KV ESD, 1.25G SFP Extended, 1.25G SFP Industrial, 1.25G SFP Lead Free, 1.25G SFP Low Power, 1.25G SFP Module, 1.25G SFP Other Optical Links, 1.25G SFP RoHS, 1.25G SFP Switch, 1.27mm/s, 1.27SOP, 100 Ohm, 100 ohm Differential, 1000000000 Times, 100BASE-FX 工业级, 100G APD, 100G Backbone, 100G DCI, 100G Ethernet HPC, 100G Ethernet Multimode, 100G Ethernet Standard, 100G High Speed, 100G Mini DWDM, 100G Optoelectronic, 100G QSFP28 SR4 I-TEMP, 100GBASE-SR4 Multirate CDR, 1060 nm Extended Temperature, 10km Reach, 12 Mounting Holes, 1310nm window, 1310T/1490R, 14 Pin Butterfly, 150mA, 1531.6nm F-tone Networks, 1531.6nm TEC Cooled, 1531.6nm 北亿纤通, 1a, 1H019 D0S20 Series, 1nm Spectral Width, 1x9 Compatible, 1x9 Pin Package, 2-Core Armored, 2-Section, 2.54mm Pitch, 2.54mm 间距, 20% to 80% Rise Time, 21.10mm Heat Sink Outside Diameter, 260ps Rise/Fall, 2800mA Current, 29 Pages Document, 3.06, 3.13-3.47V, 3.3V/5V Dual Voltage, 300,000h, 32K MAC Address, 4 channel groups, 4-Pin A-Coded, 5-page Datasheet, 50Ω Impedance, 5页规格书, 7.0mm, 8K MAC地址表, 94V-0 阻燃级, AC/DC, Add Triangular Markings, Alarm Relay, AM-Video Systems, Amplifier, Analog, Analog Photonic, APD Photodiode, Application Circuit, Approved, Attenuator Manufacturer, Auto Gain Control, Automatic Train Protection, Average launch power of OFF transmitter -30dBm, Biconic Coupler, Biconic Taper, BIDI Digital Diagnostic, BMS, Board Level Interconnect, Body, BOOT Total Height 1.55mm, BYCS-13L1-15D, Cable Cutoff, Cable Retention Test, Capacitance, Carrier Grade, CDR Switching, Certification, Chengdu, China, Chinese, Circular, Class 1 Laser Safety, CML electrical data, CMOS Level Compatible, Common, Common Mode Conversion, Comparison, compliant, Component, Component Exclusion Zone, Congestion Management, Converter, Copper Plating, CSFP-B4312-20Dxx V3.06, Damp Heat Steady State, Datacom SFP, DC12V供电, Definition, DFB Telecom Laser, DHCP Snooping, Digital Diagnostic Transceiver Controller, Disaggregated, dissipation, Domestic, Domestic Substitute, Driver, DVR, DWDM Transmission System, EN45545 Certified, Encryption Storage, ESD 静电防护, FC receptacle TYPE2(plastic connector), Forward Error Correction, FS801 Moisture Proof, FS801 Operating Temperature, FT-49-XX-XX-XXXX-XX-AMAT, FT-73-DFB Ethane, FT-73-DFB TF8, FT-RTS69 14.60mm, FT-RTS69 76 Solder, FT-RTS69 SMT, FT-RTS69 SMT 贴装, FT-Y 0~40°C, FT-Y 24V DC, FT-Y Device Name, FT-Y ERPS Profile, FT-Y Jumbo Frame, FT-Y Port Isolation, FT-Y Series User Manual, FT-Y 设备型号, FTPC217, Hardness Not Specified, Headroom, High Linearity, High Temperature High Humidity, High-tech, High-tech Industrial Park, IEC 61000-4-5 Surge, Insulation, Isolated, Isolator, ITU-T Recommendation, J599MT Mechanical Transfer, J599MT Pre-made, Logic Level, Low Phase Noise, Medical, MOSFET, MPO Connector Specifications, Near Infrared Modulator, Open Collector, Optical Signal Conditioning, Optically, Optocoupler, Package Outline, Pb-free, PCB Thickness, Photo-transistor, Photoelectric Conversion Module, Photovoltaic, PLC, Power Supply Noise Rejection, Production, QSFP-DD 56 SMD, QSFP-DD 56 Surface Mount, REACH SVHC, Reflow, Reflow Soldering, Resistance, Reverse Polarity Protection, RoHS Directive, RoHS2.0 环保, RoHS无铅, SFP Small Form Factor, Sichuan, SOP-4, SOP-4L, SOP封装, SSR, Tape & Reel, Three Bandwidth Options, TJ 0.1 UI, TSTG, UL Listed, Update Drawing Template, UPS光耦, Zero, 低烟无卤, 低输入电流光耦, 低速率光耦, 光敏晶体管, 光敏晶体管输出光耦, 光敏晶体管输出型光耦合器, 光电二极管输出光耦, 光电耦合器, 光耦合, 光耦合器, 光耦隔离, 北亿纤通科技有限公司, 四川成都, 回流焊, 回流焊接温度, 固态继电器, 固态继电器光耦, 国产光耦合器, 国产替代, 成都高新区, 散热片 黑色阳极氧化, 晶体管输出型光耦合器简称, 正向脉冲电流, 焊接时间, 电流传输比, 电源控制, 编带包装, 脉冲上升时间, 脉冲下降时间, 表面贴装, 贮存温度, 高新工业园
FT-WR系列 CXP Connector Assemblies 产品安装工艺说明 V3.06 (12× QFP 120Gb/s 高速并行 Cage+Housing 板级压接工艺 1.27mm/s 2940N Max 44.25×32.50mm PCB 6 PTH Ø2.20 0.37mm 成品孔 0.457mm #77 钻头 0.73mm 孔环 3.50mm TYP InfiniBand 100G 以太网 数据中心) | F-tone Networks 北亿纤通FT-WR系列 CXP Connector 安装工艺指南, 布线与配线管理(TYP), ±0.10, ×, 1.27mm/s, 1.40, 1.60, 10Gb/s, 12, 2, 2.95mm, 3.06, 4.00mm, 6, A, A=0.37±0.05mm, Alignment, and, Area, Array, Assembly, Automatic, B, Back, Base, Board, C, Cage, CAGE+CONNECTOR, center, Central, Channel, Component, Connector, Control, Copper, Crimping, Data, Datasheet, Design, DETAIL, Edge, Equipment, Ethernet, F-tone, Fit, Flat, Force, Gbps, Geometric, Guide, High, High-Speed, Hole, Housing, InfiniBand, Installation, Insulation, Keep, Layer, Layout, Limit, Long, Lower, Max, mm, Module, Mount, mounting, MSA, Networks, Out, Package, Pad, Parallel, PCB, Pin, Pitch, Plated, Plating, Post, Press, Press-fit, Process, Production, QC, Routing, Series, short, Side, Size, Solder, Spacing, Speed, Standard, structure, Thickness, Through, Top, Total, Transceiver, Typ, Typical, U, V, V3.06, View, Wall, 个, 个金属化通孔, 北亿纤通, 孔位, 安装, 安装孔, 封装, 布局, 形位公差, 推荐, 推荐封装尺寸, 收发器, 放大, 数据中心, 笼, 笼式连接器, 系列, 规范, 质量控制, 路, 过孔, 连接器, 通道
FT-13-DWDM116331116 8x2CH DWDM Module 16通道双向密集波分复用器 (C33/C34 1520-1570nm 100GHz ITU LC/UPC G657A1 1.0M -40~+85°C 工业级) | F-tone Networks 北亿纤通FT-13-DWDM116331116 8x2CH系列, 布线与配线管理-40, 0.2dB, 0.9mm, 1.0M, 100GHz, 100GHz通道间隔, 1520-1570nm, 16, 16CH, 1U, 1U机架, 1米尾纤, 30dB, 40dB, 45dB, 50dB, 8, 85C, 8x2通道DWDM模块, Adjacent, Bi-directional, C-band, C34, CATV, Channel, Compact, compliant, Component, Connector, C波段, DEMUX, Density, Directivity, Dual, DWDM, F-tone, Fiber, FTTH, FTTx, G657A1, Grid, High, Industrial, Insertion, Isolation, ITU, LC, LC/UPC, LC接口, Length, Loose, Loss, low, Metro, Module, Mount, Multiplexer, MUX, Network, Networks, Non-adjacent, Optic, Package, PDL, PMD, Rack, Return, RoHS, Spacing, System, Telecom, Temperature, Tube, V3.06, Version, WDM, WDM系统, x, 北亿纤通, 城域网, 无源光器件, 无铅, 有线电视, 电信网络
FT-AJ 3+3CH DWDM MUX&DEMUX V3.07 3+3通道双向密集波分复用器 C18/C46 + 50% 监测端口 (1520-1570nm G657A2 1.5M -40~+70°C) | F-tone Networks 北亿纤通FT-AJ 3+3CH DWDM, 布线与配线管理-40, +70, 0.11nm, 0.3dB, 0.5dB, 1.5M, 1.5米尾纤, 1%, 100GHz, 100GHz间隔, 1520, 1520-1570nm, 1570nm, 3+3通道密集波分复用器, 300mW, 30dB, 4.5dB, 40dB, 45dB, 50%, 50dB, 70C, 9/125um, 900um, 900μm松套管, ABS, Access, Adjacent, Amplifier, Bi-directional, Bidirectional, Box, C-band, C18/C46, C18通道, C46通道, Cable, Channel, Coarse, Compact, compliant, Component, CW, C波段, DEMUX, Directivity, Dual, DWDM, DWDM复用解复用, Enterprise, F-tone, FC, Fiber, FT-AJ, FTTB, FTTH, FTTx, G.657A2单模光纤, G.694.1, G657A2, GR-1209, GR-1221, Grid, High, Industrial, Insertion, Isolation, ITU, ITU-T, LC, Length, Loose, Loss, low, Metro, Module, Monitor, MUX, MUX&DEMUX, Network, Networks, Non-adjacent, Optic, Optical, Optional, Package, Passband, Passive, PDL, Port, Power, Reliability, Return, RoHS, SC, Single, Singlemode, Spacing, ST, Stability, Standard, System, Tap, Telcordia, Telecom, to, Tube, TV, Upgrade, V3.07, Version, Wavelength, WDM, WDM系统, 企业网, 低插入损耗, 偏振相关损耗, 光功率, 光纤放大器, 北亿纤通, 单纤双向, 可选光口, 可靠性, 回波损耗, 城域接入网, 塑料封装, 插入损耗, 方向性, 无源光器件, 无铅环保, 有线电视网络, 电信网络, 监测分光, 监测端口, 相邻通道隔离, 粗波分复用, 通带, 非相邻隔离, 高可靠性, 高稳定性, 高隔离度
FT-AJ 3CH DWDM MUX&DEMUX 3通道密集波分复用器 C18/C46 + 50% 监测端口 (1520-1570nm G657A2 1.5M -40~+70°C) | F-tone Networks 北亿纤通FT-AJ 3CH DWDM, 布线与配线管理-40, +70, 0.11nm, 0.3dB, 0.5dB, 1.5M, 1.5米尾纤, 1%, 100GHz, 100GHz间隔, 1520, 1520-1570nm, 1570nm, 3, 300mW, 30dB, 3CH, 4.5dB, 40dB, 45dB, 50%, 50dB, 70C, 9/125um, 900um, 900μm松套管, ABS, Access, Adjacent, Amplifier, Box, C-band, C18/C46, C18通道, C46通道, Cable, Channel, Coarse, Compact, compliant, Component, CW, C波段, DEMUX, Directivity, DWDM, DWDM复用解复用, Enterprise, F-tone, FC, Fiber, FT-AJ, FTTB, FTTH, FTTx, G.657A2单模光纤, G.694.1, G657A2, GR-1209, GR-1221, Grid, High, Industrial, Insertion, Isolation, ITU, ITU-T, LC, Length, Loose, Loss, low, Metro, Module, Monitor, MUX, MUX&DEMUX, Network, Networks, Non-adjacent, Optic, Optical, Optional, Package, Passband, Passive, PDL, Port, Power, Reliability, Return, RoHS, SC, Singlemode, Spacing, ST, Stability, Standard, System, Tap, Telcordia, Telecom, to, Tube, TV, Wavelength, WDM, WDM系统, 企业网, 低插入损耗, 偏振相关损耗, 光功率, 光纤放大器, 北亿纤通, 可选光口, 可靠性, 回波损耗, 城域接入网, 塑料封装, 插入损耗, 方向性, 无源光器件, 无铅环保, 有线电视网络, 电信网络, 监测分光, 监测端口, 相邻通道隔离, 粗波分复用, 通带, 非相邻隔离, 高可靠性, 高稳定性, 高隔离度
FT-S59-AH019-D6S03 QSFP28 2×1 CAGE+CONNECTOR 双端口屏蔽笼式连接器组件 (100G/28G SFF-8662) | F-tone Networks 北亿纤通FT-S59-AH019-D6S03系列, QSFP28 CAGE+CONNECTOR 笼式连接器, 其他配件, 布线与配线管理0.5A, 100G, 2, 2X1, 30V, 94V-0, AC, Alloy, Assembly, Cage, CAGE+CONNECTOR, Component, Connector, Contact, Copper, Current, Cutout, DC, Dielectric, Dimensions, Drawing, EMI, EMI弹片, F-tone, Footprint, Free, Gold, Hot-Pluggable, Layout, Lead, Light, Matte, Mechanical, mm, Module, Networks, Nickel, Operating, Panel, PCB, PCB布局, Pipe, Plating, Port, QSFP28, QSFP28连接器, Rated, Recommended, Resistance, REV:A, RoHS, SFF-8662, SFF-8665, Shielded, Spring, Stainless, Steel, Temperature, Tin, Transceiver, UL, Voltage, Withstand, 不锈钢, 北亿纤通, 北亿纤通科技, 工作温度, 工程图, 接触电阻, 无铅, 机械尺寸, 热插拔, 电磁兼容, 耐压, 镀金, 镀镍, 阻燃, 面板开孔, 额定电压