FTCS-8528G-02D 28.05Gbps SFP28 SR Transceiver 850nm 100m MMF LC Duplex

28.05Gbps SFP28 Transceiver, Multi Mode, 100m Reach
FTCS-8528G-02D

Product Features

  • Supports up to 28.05Gbps bit rates
  • Hot-pluggable SFP+ footprint
  • 850nm VCSEL laser and PIN photodiode
  • 100m over M5F MMF (50/125 um OM4)
  • 70m over M5E MMF (50/125um OM3)
  • 20m on MMF (50/125um OM2)
  • Compliant with SFP+ MSA and SFF-8472 with duplex LC receptacle
  • Compatible with RoHS
  • Single +3.3V power supply
  • Real Time Digital Diagnostic Monitoring
  • Operating case temperature:

Standard: 0 to +70°C

Applications

  • Tri-Rate 8.5/14.025/28.05 Gb/s Fibre Channel

Description

The SFP28 transceivers are high performance, cost effective modules supporting data rate of 28.05Gbps over multimode fiber.

The transceiver consists of three sections: a VCSEL laser transmitter, a PIN photodiode integrated with a trans-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements.

The transceivers are compatible with SFP Multi-Source Agreement and SFF-8472 digital diagnostics functions.

Temp

Vcc

LD Bias

Tx Power

Rx Power

TD+/-

TxFault

TxDis

LOS

RD+/-

POWER

SCL

SDA

LD Driver

LD

PIN+TIA

Post Amp

I2C Controller

EEPROM

ADC/DAC

Transceiver functional diagram

Absolute Maximum Ratings

Parameter

Symbol

Min

Max

Unit

Supply Voltage

Vcc

-0.5

4

V

Storage Temperature

Ts

-40

+85

°C

Operating Humidity

5

85

%

Recommended Operating Conditions

Parameter

Symbol

Min

Typical

Max

Unit

Operating Case Temperature

Tc

0

+70

°C

Power Supply Voltage

Vcc

3.135

3.30

3.465

V

Power Supply Current

Icc

300

mA

Data Rate

28.05

Gbps

Optical and Electrical Characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Notes

Transmitter

Centre Wavelength

λc

840

850

860

nm

Spectral Width(RMS)

Δλ

0.57

nm

Side-Mode Suppression Ratio

SMSR

dB

Average Output Power

Pout

-6.2

2

dBm

1

Extinction Ratio

ER

2.0

dB

Data Input Swing Differential

VIN

180

950

mV

2

Input Differential Impedance

ZIN

90

100

110

Ω

TX Disable

Disable

2.0

Vcc

V

Enable

0

0.8

V

TX Fault

Fault

2.0

Vcc

V

Normal

0

0.8

V

Receiver

Centre Wavelength

λc

840

850

860

nm

Receiver Sensitivity

SEN

-10.2

dBm

3

Receiver Overload

2

dBm

3

LOS De-Assert

LOSD

-13

dBm

LOS Assert

LOSA

-30

dBm

LOS Hysteresis

0.5

4

dB

Data Output Swing Differential

Vout

500

900

mV

4

LOS

High

2.0

Vcc

V

Low

0.8

V

Notes:

1. The optical power is launched into MMF.

2. PECL input, internally AC-coupled and terminated.

3. For 32GFC with FEC, receiver sensitivity is defined at 1E-6 BER level, not 1E-12 BER level.

4. Internally AC-coupled.

Timing and Electrical

Parameter

Symbol

Min

Typical

Max

Unit

Tx Disable Negate Time

t_on

2

ms

Tx Disable Assert Time

t_off

100

µs

Time To Initialize, including Reset of Tx Fault

t_init

300

ms

Tx Fault Assert Time

t_fault

100

µs

Tx Disable To Reset

t_reset

10

µs

LOS Assert Time

t_loss_on

100

µs

LOS De-assert Time

t_loss_off

100

µs

Serial ID Clock Rate

f_serial_clock

100

400

KHz

MOD_DEF (0:2)-High

VH

2

Vcc

V

MOD_DEF (0:2)-Low

VL

0.8

V

Diagnostics

Parameter

Range

Unit

Accuracy

Calibration

Temperature

0 to +70

°C

±3°C

Internal

Voltage

3.0 to 3.6

V

±3%

Internal

Bias Current

0 to 15

mA

±10%

Internal

TX Power

-6.2 to 2

dBm

±3dB

Internal

RX Power

-12 to 2

dBm

±3dB

Internal

Digital Diagnostic Memory Map

The transceivers provide serial ID memory contents and diagnostic information about the present operating conditions by the 2-wire serial interface (SCL, SDA).

The diagnostic information with internal calibration or external calibration all are implemented, including received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring.

The digital diagnostic memory map specific data field defines as following.

Pin Descriptions

Pin

Signal Name

Description

Plug Seq.

Notes

1

VEET

Transmitter Ground

1

2

TX FAULT

Transmitter Fault Indication

3

Note 1

3

TX DISABLE

Transmitter Disable

3

Note 2

4

SDA

SDA Serial Data Signal

3

5

SCL

SCL Serial Clock Signal

3

6

MOD_ABS

Module Absent. Grounded within the module

3

7

RS0

Not Connected

3

8

LOS

Loss of Signal

3

Note 3

9

RS1

Not Connected

3

10

VEER

Receiver ground

1

11

VEER

Receiver ground

1

12

RD-

Inv. Received Data Out

3

Note 4

13

RD+

Received Data Out

3

Note 4

14

VEER

Receiver ground

1

15

VCCR

Receiver Power Supply

2

16

VCCT

Transmitter Power Supply

2

17

VEET

Transmitter Ground

1

18

TD+

Transmit Data In

3

Note 5

19

TD-

Inv. Transmit Data In

3

Note 5

20

VEET

Transmitter Ground

1

Notes:

Plug Seq.: Pin engagement sequence during hot plugging.

1) TX Fault is an open collector output, which should be pulled up with a 4.7k~10kΩ resistor on the host board to a voltage between 2.0V and Vcc+0.3V. Logic 0 indicates normal operation; Logic 1 indicates a laser fault of some kind. In the low state, the output will be pulled to less than 0.8V.

2) Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V.

3) LOS is open collector output. Should be pulled up with 4.7k~10kΩ on host board to a voltage between 2.0V and 3.6V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.

4) RD-/+: These are the differential receiver outputs. They are internally AC-coupled 100 differential lines which should be terminated with 100Ω (differential) at the user SERDES.

5) TD-/+: These are the differential transmitter inputs. They are internally AC-coupled, differential lines with 100Ω differential termination inside the module.

Recommended Interface Circuit

Mechanical Dimensions

GO9T3@RTS2K1055WJY6TDUY

Ordering information

Part Number

Product Description