FT-13系列 4CH DWDM 8skip0 模块 V3.06 (16波长 1520-1570nm 100GHz ITU-T G.694.1 4个8S0子模块 C24~C55 C24/26/28/30+C32/34/36/38+C40/42/44/46+C48/50/52/54 插损≤2.0dB 隔离≥15dB PDL≤0.2dB PMD≤0.2ps 300mW G657A1 0.9mm松套管 80x60x12mm) | F-tone Networks 北亿纤通

The FT-13 Series 4CH DWDM 8skip0 Module Spec V3.06 is a 16-wavelength DWDM multiplexer/demultiplexer module combining 4 × 8skip0 (8-skip-0) filter sub-modules with 100GHz ITU-T channel spacing in C-band manufactured by F-tone Networks(北亿纤通). The FT-13 4CH DWDM 8skip0 module uses 4 × 8S0 (8-skip-0) sub-modules to provide 16 wavelengths across C24 to C55 (1520~1570nm, C-band). 4 channel groups: C24/C26/C28/C30 + C32/C34/C36/C38 + C40/C42/C44/C46 + C48/C50/C52/C54 (each 8skip0 group covers 4 wavelengths with 100GHz spacing within the group, and 800GHz spacing between groups). Channel spacing 100GHz (0.8nm), ITU-T G.694.1 standard. Insertion loss ≤2.0dB (including connector loss). Isolation ≥15dB. PDL ≤0.2dB, PMD ≤0.2ps, Ripple ≤0.5dB, Directivity ≥50dB, Return loss ≥45dB. Maximum power handling 300mW. Operating temperature -10~+70°C, Storage temperature -40~+85°C. G657A1 bend-insensitive single-mode fiber with 0.9mm loose tube, 1.0±0.05m fiber length. Compact 80x60x12mm package. MUX and DEMUX inverse port mapping (MUX: C24→C54 top-to-bottom, DEMUX: C48→C24 top-to-bottom). 12 main applications: WDM Network + Metro Network + Long-haul + Telecom + CATV + FTTH + 5G Fronthaul + DCI + OADM + ROADM + PON/GPON/XGS-PON + OTN.

本产品为【FT-13系列 4CH DWDM 8skip0 模块 V3.06】产品线。F-tone Networks 第二款”FT-13系列 DWDM模块”产品(**第一款为 FT-13-DWDM116331116 8x2CH 系列 ID 2649**)。本款采用 **4 个 8S0(8-skip-0)子模块**组成 **16 波长 DWDM 复用/解复用器**,**C24~C55 工作波长(1520~1570nm)+ 100GHz ITU-T G.694.1 标准 + 插入损耗 ≤2.0dB + 隔离度 ≥15dB + 300mW 高功率承载 + G657A1 弯曲不敏感光纤 + 80×60×12mm 紧凑封装**。

🔬 关键差异化亮点:F-tone 首款”4CH DWDM 8skip0″16波长复用/解复用器

4×8S0 Sub-modules — 4 个 8skip0 滤波子模块级联
16 Wavelengths — 16 波长 DWDM 复用/解复用器
C24-C55 — C24 至 C55(1520-1570nm C-band)
4 Channel Groups — 4 个通道组(C24/26/28/30 + C32/34/36/38 + C40/42/44/46 + C48/50/52/54)
100GHz Spacing — 100GHz(0.8nm)通道间隔,ITU-T G.694.1 标准
IL ≤2.0dB — 插入损耗 ≤2.0dB(含连接头损耗)
Isolation ≥15dB — 隔离度 ≥15dB
PDL ≤0.2dB — 偏振相关损耗 ≤0.2dB
PMD ≤0.2ps — 偏振模色散 ≤0.2ps
Ripple ≤0.5dB — 平坦度 ≤0.5dB
Directivity ≥50dB — 方向性 ≥50dB
Return Loss ≥45dB — 回波损耗 ≥45dB
300mW High Power — 最大光功率承载 300mW
-10~+70°C Operating — 工作温度 -10~+70°C
-40~+85°C Storage — 储存温度 -40~+85°C
G657A1 Fiber — G657A1 弯曲不敏感单模光纤
0.9mm Loose Tube — 0.9mm 松套管
1.0±0.05m Fiber — 光纤长度 1.0±0.05m
80x60x12mm Package — 紧凑 80×60×12mm 封装
MUX/DEMUX Inverse — MUX 与 DEMUX 端口映射互逆
12 Applications — WDM/Metro/Long-haul/Telecom/CATV/FTTH/5G/DCI/OADM/ROADM/PON/OTN

🔄 F-tone FT-13系列 DWDM/CCWDM模块产品线 3 SKU 对比

维度 FT-13_3CH CCWDM(ID 3360) FT-13-DWDM116331116 8x2CH(ID 2649) FT-13 4CH DWDM 8skip0(本篇 V3.06)
类型 3CH 粗波分 CCWDM 模块 8x2CH DWDM 模块 4CH DWDM 8skip0 模块
通道数 3 通道 16 波长(8 通道 ×2) 16 波长(4 通道组 ×4 通道)
工作波长 1310/1410/1510nm(CCWDM 粗波分) DWDM C-band(推测) 1520~1570nm(C24~C55)
通道间隔 20nm(CCWDM 标准) 200GHz 推测 100GHz(0.8nm)
波长方案 CCWDM 3 波长独立 DWDM 8x2CH 标准 8-skip DWDM 8skip0 4 个 8S0 子模块
插入损耗 CCWDM 标准 DWDM 标准 ≤2.0dB(含连接头)
封装 CCWDM 标准 DWDM 8x2CH 80×60×12mm 紧凑
应用 5G 前传/接入网/低成本 WDM DWDM 城域网/长距 WDM/Metro/Long-haul/Telecom/CATV/FTTH/5G/DCI/OADM/ROADM/PON/OTN

1. 产品简介(Product Introduction)

FT-13 4CH DWDM 8skip0 模块是 F-tone Networks 推出的 16 波长 DWDM 复用/解复用器,采用 4 个 8S0(8-skip-0)滤波子模块级联方案,在 C-band(1520-1570nm)提供 16 个标准 100GHz 间隔的 ITU-T DWDM 波长通道,适用 WDM/Metro/Long-haul/Telecom/CATV/FTTH/5G Fronthaul/DCI/OADM/ROADM/PON/OTN 等多场景。

2. 性能规格(Performance Specifications)

2.1 完整性能参数表(Full Specifications)

参数/Parameters Specifications Unit
工作波长/Operating Wavelength 1520~1570 nm
通道/Channel C24/C26/C28/C30 (C24~C31) nm
C32/C34/C36/C38 (C32~C39) nm
C40/C42/C44/C46 (C40~C47) nm
C48/C50/C52/C54 (C48~C55) nm
通道间隔/Channel Spacing 100 GHz
插入损耗¹/Insertion Loss¹ ≤2.0 dB
隔离度/Isolation ≥15 dB
偏振相关损耗/Polarization Dependent Loss (PDL) ≤0.2 dB
偏振模色散/Polarization Mode Dispersion (PMD) ≤0.2 ps
平坦度/Ripple ≤0.5 dB
方向性/Directivity ≥50 dB
回波损耗/Return Loss ≥45 dB
最大光功率/Maximum Power Handling 300 mW
工作温度/Operating Temperature -10~+70
储存温度/Storage Temperature -40~+85
光纤类型/Fiber Type 0.9mm tube loose, G657A1
光纤长度/Fiber Length 1.0±0.05 m
封装尺寸/Package Size 80×60×12 mm
📌 备注/Notes:

  • 所有插入损耗值都包括连接头之损耗值(All insertion loss values include connector loss)
  • 本规格参数均为典型值(typical values),需在订单/合同中以书面形式确认

3. 通道详细分布(Channel Distribution)

3.1 4 个 8S0 通道组(4 × 8S0 Channel Groups)

通道组 子模块 波长(ITU-T 100GHz 通道) 中心波长(典型) 组内间隔 组间间隔
Group 1 8S0-1 C24 / C26 / C28 / C30 1520.25 / 1521.85 / 1523.45 / 1525.05 nm(推测) 100GHz
Group 2 8S0-2 C32 / C34 / C36 / C38 1530.70 / 1532.30 / 1533.90 / 1535.50 nm(推测) 100GHz 800GHz
Group 3 8S0-3 C40 / C42 / C44 / C46 1541.15 / 1542.75 / 1544.35 / 1545.95 nm(推测) 100GHz 800GHz
Group 4 8S0-4 C48 / C50 / C52 / C54 1551.60 / 1553.20 / 1554.80 / 1556.40 nm(推测) 100GHz 800GHz
📌 “8skip0” 波长方案说明:

  • 8skip0 含义:每个 8S0 子模块覆盖 4 个 100GHz 间隔波长(如 C24/C26/C28/C30),组内波长间隔 100GHz
  • 组间间隔:每个 8S0 子模块与下一个 8S0 子模块之间间隔 800GHz(8 × 100GHz),对应于 ITU-T 100GHz 网格上的 8 通道”跳跃”
  • 4 个 8S0 子模块级联后,总波长覆盖 C24 至 C55,共 16 个波长
  • 优势:使用 4 个标准 8S0 子模块即可实现 16 波长 DWDM,比传统 16 通道 DWDM 模块成本更低、结构更简单

4. MUX/DEMUX 端口映射(Port Mapping)

FT-13 4CH DWDM 8skip0 MUX DEMUX 端口映射

图1 FT-13 4CH DWDM 8skip0 模块 MUX 与 DEMUX 端口映射(V3.06)— 4 个 8S0 子模块 + COM 公共端 + 4 个通道组(C24/26/28/30 + C32/34/36/38 + C40/42/44/46 + C48/50/52/54)

4.1 MUX(多路复用器)端口映射

子模块(从上到下) 通道组 波长(ITU-T 100GHz 通道)
8S0-1 Group 1 C24 / C26 / C28 / C30
8S0-2 Group 2 C32 / C34 / C36 / C38
8S0-3 Group 3 C40 / C42 / C44 / C46
8S0-4 Group 4 C48 / C50 / C52 / C54
公共端 COM

4.2 DEMUX(多路解复用器)端口映射

子模块(从上到下) 通道组 波长(ITU-T 100GHz 通道)
8S0-1 Group 4 C48 / C50 / C52 / C54
8S0-2 Group 3 C40 / C42 / C44 / C46
8S0-3 Group 2 C32 / C34 / C36 / C38
8S0-4 Group 1 C24 / C26 / C28 / C30
公共端 COM
📌 重要说明:

  • MUX 与 DEMUX 端口映射为互逆关系(Inverse Port Mapping)
  • MUX:信号从 4 个 8S0 子模块(16 个通道)复用到 COM 公共端
  • DEMUX:信号从 COM 公共端解复用到 4 个 8S0 子模块(16 个通道)
  • 实际部署中:MUX 用于发射端(Tx),DEMUX 用于接收端(Rx)

5. 封装尺寸(Package Dimensions)

FT-13 4CH DWDM 8skip0 80x60x12mm 壳体工程图

图2 FT-13 4CH DWDM 8skip0 模块 80×60×12mm 壳体工程图(V3.06)— 顶部全剖视图 + 左视图(5 个 φ3.0 通孔)+ 右下正视图(80×60mm + 4 个 M3 固定孔)

5.1 封装尺寸详情(Package Dimension Details)

参数 单位
总长 L 80 mm
总宽 W 60 mm
总高 H 12 mm
壁厚 均匀(剖视图显示总高度 9mm + 壁厚)
安装孔 4 × M3 过孔(横向 75±0.10mm × 纵向 55±0.10mm)
侧通孔 5 × φ3.0 通孔(间距 5mm)
内部安装位纵向间距 16.9mm / 7.2mm
固定柱 内含安装固定柱结构(剖视图)
密封槽 边缘虚线表示内部密封槽
📌 重要说明:

  • 封装尺寸 80×60×12mm,紧凑型设计,适用机架/机箱高密度安装
  • 4 个 M3 安装孔提供稳定的 PCB/机箱固定
  • 5 个 φ3.0 侧通孔可作为光纤穿出口或额外的固定孔
  • 边缘密封槽提供良好的气密性(密封等级取决于具体产品)

6. 关键差异化优势(Key Differentiation Advantages)

🎯 FT-13 4CH DWDM 8skip0 6 大关键优势

🏆 16λ 高密度 DWDM — 16 波长 100GHz ITU-T 标准 DWDM 复用/解复用
🏆 4×8S0 创新方案 — 4 个 8S0 子模块级联,比传统 16 通道 DWDM 更具成本优势
🏆 C-band 全覆盖 — C24-C55 完整覆盖 1520-1570nm C-band
🏆 高功率承载 — 最大光功率 300mW,适用高功率 DWDM 系统
🏆 G657A1 弯曲不敏感 — G657A1 弯曲不敏感光纤,适用复杂布线环境
🏆 紧凑封装 — 80×60×12mm 紧凑封装,节省机架/机箱空间
🏆 低插损 — ≤2.0dB 插入损耗(含连接头),适用长距 DWDM 系统
🏆 高隔离 — ≥15dB 隔离度,保证 16 通道间无串扰

7. 应用场景(Typical Applications)

🚀 FT-13 4CH DWDM 8skip0 12 大典型应用

WDM Network — WDM 网络
Metro Network — 城域网
Long-haul Network — 长途网络
Telecom Network — 电信网络
CATV Network — 有线电视
FTTH — 光纤到户
5G Fronthaul — 5G 前传
DCI — 数据中心互联
OADM — 光分插复用器
ROADM — 可重构 OADM
PON/GPON/XGS-PON — 无源光网络
OTN — 光传送网

8. 注意事项及维护(Precautions & Maintenance)

  • 🔸 清洁光纤端面:使用前请用专业光纤清洁工具清洁所有光纤端面,不使用时请带好防尘帽
  • 🔸 最小弯曲半径:G657A1 弯曲不敏感光纤最小弯曲半径 ≥ 15mm(短期)/ ≥ 30mm(长期),避免过度弯曲
  • 🔸 最大光功率:本模块最大承载光功率 300mW,请勿超过此值以避免损坏内部光学元件
  • 🔸 温度范围:工作温度 -10~+70°C,储存温度 -40~+85°C
  • 🔸 MUX/DEMUX 配对使用:本模块成对使用(MUX 用于发射端,DEMUX 用于接收端),请确认端口映射方向
  • 🔸 8S0 子模块对应关系:MUX 端 8S0-1 对应 C24-C30,DEMUX 端 8S0-1 对应 C48-C54(互逆)
  • 🔸 光纤长度 1.0±0.05m:本模块标配 1.0m ± 5cm 光纤(0.9mm 松套管),如需定制请与销售联系
  • 🔸 安装固定:使用 4 × M3 螺丝固定模块,扭矩 ≤ 0.5 N·m,避免损坏壳体

🌐 F-tone Networks 北亿纤通 — Company Information

Company Name(公司名):北亿纤通科技有限公司 | F-tone Networks

Region(地区):China Sichuan Tianfu New Area Chengdu High-tech Industrial Park(中国四川天府新区成都高新区高新工业园)

Service Area(服务区域):Global(全球)

Tel(企业电话):+86-28-85255257-812

Fax(企业传真):+86-28-85977702

Add(地址):A-1 building, High tech Industrial Park, Chengdu, Sichuan, China

Web(网站):http://www.f-tone.com

Email(邮箱):sales@f-tone.com

本产品为【FT-13系列 4CH DWDM 8skip0 模块 V3.06】产品线。详细信息请联系我们的销售人员,谢谢!

Important Notice 重要通知

Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.