CSFP-B4312-20Dxx 1.25G BIDI 20km CSFP MSA 2.0 Option 2 Transceiver V3.06 (2ch 双通道 1490T/1310R 2 SKU 标准/工业级 DDM SFP MSA SFF-8074i 单LC接口 单纤双向 Gigabit Ethernet Fibre Channel) | F-tone Networks 北亿纤通

The CSFP-B4312-20Dxx 1.25Gb/s CSFP BIDI Transceiver V3.06 is a 1.25Gb/s 1490T/1310R 20km Compact SFP (CSFP) Bi-Directional (BIDI) transceiver manufactured by F-tone Networks(北亿纤通). The transceiver integrates two Bi-Directional (BIDI) transceivers in one SFP package, supporting up to 1.25Gb/s data links, single Duplex LC connector (one LC interface carries 2 BIDI channels). 1490nm DFB laser transmitter, up to 20km on 9/125um SMF, single +3.3V power supply, metal enclosure for lower EMI. Compliant with CSFP MSA 2.0 (Option 2) + SFP MSA SFF-8074i. 2 SKU: CSFP-B4312-20D (0~+70°C commercial) + CSFP-B4312-20DI (-40~+85°C industrial). Supports DDM Digital Diagnostic Monitoring (Temperature + Voltage + Bias Current + TX Power + RX Power 5 parameters with Internal Calibration). For Gigabit Ethernet + Fibre Channel + FTTx + FTTH + single-fiber bidirectional high-density optical communication.

本产品为【CSFP-B4312-20Dxx 1.25G BIDI 20km 双通道 CSFP 光模块 V3.06】产品线,2 SKU 标准/工业级 1490T/1310R 20km CSFP MSA 2.0 Option 2 + SFP MSA SFF-8074i 1000BASE Gigabit Ethernet + Fibre Channel 系列

🛡️ 关键差异化亮点:F-tone 第二款”CSFP 紧凑型 SFP”+”BIDI 双向”光模块(CSFP-B3412 40km 姊妹产品)

Two BiDi in 1 SFP — 2 个 BIDI 收发器在 1 个 SFP 封装中
1.25Gb/s Data Rate — 1.25Gb/s 数据速率
1490T/1310R BIDI — 1490nm 发射 + 1310nm 接收单纤双向
20km SMF Reach — 20km 单模传输
Single LC Interface — 单 LC 接口承载 2 个 BIDI 通道
CSFP MSA 2.0 (Option 2) — CSFP MSA 2.0 Option 2 合规
SFP MSA SFF-8074i — SFP MSA SFF-8074i 合规
Hot-pluggable SFP Footprint — 热插拔 SFP 封装
1490nm DFB Laser — 1490nm DFB 激光器
-9~-3 dBm Output Power — 光功率 -9 ~ -3 dBm
6.0dB Extinction Ratio — 消光比 6.0dB
1470-1510nm Center Wavelength — 中心波长 1470-1510nm
1nm Spectral Width — 谱宽 1nm RMS
30dB SMSR — 边模抑制比 30dB
260ps Rise/Fall Time — 上升/下降时间 260ps
-22.5dBm Sensitivity — 接收灵敏度 -22.5dBm
-3dBm Overload — 接收过载 -3dBm
LOS De-Assert -25dBm — LOS 解除告警 -25dBm
LOS Assert -40dBm — LOS 告警 -40dBm
0.5-5dB Hysteresis — 迟滞 0.5-5dB
DDM Internal Calibration — DDM 数字诊断 + 内部校准
Class 1 Laser Safety — Class 1 激光安全
RoHS 2 (2011/65/EU) — RoHS 2 合规
Lead Free — 无铅
2 SKU: Commercial/Industrial — 2 SKU:商业级/工业级

🛡️ BIDI 单纤双向 关键特性(BIDI Single-Fiber Bidirectional Key Features)

Single Fiber Bidirectional — 单纤双向(1 根光纤双向传输)
1490nm TX / 1310nm RX — 1490nm 发射 + 1310nm 接收
WDM BIDI — WDM 单纤双向技术
Single LC Connector — 单 LC 接口承载 2 通道
节省光纤 50% — 单纤双向节省 50% 光纤
高密度端口 — 1 个 SFP 封装 = 2 个 BIDI 通道

🔄 CSFP 系列 2 SKU 对比(与 F-tone 已有 CSFP-B3412-40Dxx 系列 1.25G BIDI 40km 双通道对比)

维度 CSFP-B4312-20Dxx(本篇 V3.06) CSFP-B3412-40Dxx 系列(ID 3208,姊妹产品)
类型 CSFP 紧凑型 SFP BIDI 双向 CSFP 紧凑型 SFP BIDI 双向
通道数 2 通道 BIDI 2 通道 BIDI
波长 1490T/1310R 1490T/1310R(推测)
距离 20km 40km
封装 CSFP MSA 2.0 (Option 2) + SFP MSA SFF-8074i CSFP MSA 2.0 (Option 2) + SFP MSA SFF-8074i
光纤 SMF(单模 9/125um) SMF(单模 9/125um)
DDM Yes(5 参数 + 内部校准) Yes(5 参数 + 内部校准)
2 SKU 标准(0~70°C)+ 工业级(-40~85°C)

1. 主要特性(Product Features)

  • 🚀 Two Bi-Directional transceivers in one SFP package — 2 个 BIDI 收发器在 1 个 SFP 封装中
  • 🚀 Up to 1.25Gb/s data links — 最高 1.25Gb/s 数据速率
  • 🚀 Duplex LC connector — Duplex LC 接口(单 LC 承载 2 通道)
  • 🚀 Hot-pluggable SFP footprint — 热插拔 SFP 封装
  • 🚀 1490nm DFB laser transmitter — 1490nm DFB 激光器发射
  • 🚀 RoHS compliant and Lead Free — RoHS 合规 + 无铅
  • 🚀 Up to 20Km on 9/125um SMF — 最远 20km 单模光纤(9/125um G.652)
  • 🚀 Metal enclosure for lower EMI — 金属外壳降低 EMI
  • 🚀 Single +3.3V power supply — 单 3.3V 电源
  • 🚀 Compliant with CSFP MSA 2.0 (Option 2) — CSFP MSA 2.0 (Option 2) 合规
  • 🚀 Commercial and industrial operating temperature optional — 商业级/工业级温度可选
  • 🚀 SFP MSA SFF-8074i Compliant — SFP MSA SFF-8074i 合规
CSFP-B4312-20Dxx 主要特性

CSFP-B4312-20Dxx 1.25G CSFP BIDI Transceiver V3.06 主要特性(image1)— 2 个 BIDI 收发器 + Duplex LC + 1490nm DFB + 20km SMF + Hot-pluggable SFP + RoHS + Single 3.3V + CSFP MSA 2.0 Option 2 + SFP MSA SFF-8074i

2. 应用(Applications)

  • 🚀 Gigabit Ethernet — 千兆以太网光链路
  • 🚀 Fibre Channel — 光纤通道

3. 合规性(Regulatory Compliance)

项目(Item) 合规标准(Compliance Standard)
ESD to the Electrical PINs compatible with MIL-STD-883 Method 3015
ESD to the Single LC Receptacle compatible with IEC 61000-4-2
Immunity compatible with IEC 61000-4-3
EMI compatible with FCC Part 15 Class B + EN55022 Class B (CISPR 22B) + VCCI Class B
Laser Eye Safety compatible with FDA 21CFR 1040.10 and 1040.11 + EN60950, EN (IEC) 60825-1,2
RoHS compliant with RoHS 2 (2011/65/EU)

4. 绝对最大额定值(Absolute Maximum Ratings)

参数(Parameter) 符号(Symbol) 最小(Min) 最大(Max) 单位(Unit)
电源电压(Supply Voltage) Vcc -0.5 +4.0 V
存储温度(Storage Temperature) Ts -40 +85 °C
工作湿度(Operating Humidity) RH 0 85 %

5. 推荐工作条件(Recommended Operating Conditions)

参数(Parameter) 符号(Symbol) 最小(Min) 典型(Typical) 最大(Max) 单位(Unit)
工作壳温(Operating Case Temperature) Tc 0 +70 °C
-40 +85 °C
电源电压(Power Supply Voltage) Vcc 3.13 3.30 3.47 V
电源电流(Power Supply Current) Icc 500 mA
数据速率(Data Rate) 1.25 Gbps
9/125um G.652 SMF 最大距离(Max Reach) Lmax 20 km

6. 光学和电气特性(Optical and Electrical Characteristics)

6.1 发射器(Transmitter)

参数(Parameter) 符号(Symbol) 最小(Min) 典型(Typical) 最大(Max) 单位(Unit) 说明(Notes)
中心波长(Centre Wavelength) λc 1470 1490 1510 nm
谱宽 RMS(Spectral Width RMS) Δλ 1 nm
边模抑制比(Side-Mode Suppression Ratio) SMSR 30 dB
平均输出功率(Average Output Power) Pout -9 -3 dBm Note 1
消光比(Extinction Ratio) ER 6.0 dB
光上升/下降时间(Optical Rise / Fall Time) tr / tf 260 ps Note 2

6.2 接收器(Receiver)

参数(Parameter) 符号(Symbol) 最小(Min) 典型(Typical) 最大(Max) 单位(Unit) 说明(Notes)
中心波长(Centre Wavelength) λc 1260 1360 nm
接收灵敏度(Receiver Sensitivity) -22.5 dBm Note 3, 4
接收过载(Receiver Overload) -3 dBm
LOS De-Assert LOSD -25 dBm
LOS Assert LOSA -40 dBm
LOS Hysteresis 0.5 5 dB
LOS High 2.0 Vcc V
Low 0 0.8 V
💡 Notes:

  • Note 1: Class 1 Laser Safety
  • Note 2: Unfiltered, 20-80%. Complies with Gigabit Ethernet eye masks when filtered
  • Note 3: Measured with conformance signals defined in FC-PI-2 Rev. 10.0 specifications
  • Note 4: Measured with PRBS 2^7-1 at 10^-12 BER

7. 数字诊断监控(DDM Digital Diagnostic Monitoring)

参数(Parameter) 范围(Range) 单位(Unit) 精度(Accuracy) 校准(Calibration)
温度(Temperature) 0 to +70 °C ±3°C Internal
-40 to +85 °C ±3°C Internal
电压(Voltage) 2.97 to 3.63 V ±3% Internal
偏置电流(Bias Current) 0 to 100 mA ±10% Internal
TX 功率(TX Power) -9 to -3 dBm ±3dB Internal
RX 功率(RX Power) -22.5 to -3 dBm ±3dB Internal

8. EEPROM 内存映射(EEPROM Information / Memory Map)

CSFP-B4312-20Dxx EEPROM 内存映射

CSFP-B4312-20Dxx 1.25G CSFP BIDI Transceiver V3.06 EEPROM 内存映射(image5)— 2ch Compact SFP (option 2) Memory Map,A0h(1010000X) 和 B0h(1011000X) 是 Ch1/Ch2 串行 ID 地址,A2h(1010001X) 和 B2h(1011001X) 是 Ch1/Ch2 数字诊断地址

Memory map for 2ch Compact SFP (option 2) is illustrated in below figure. A0h (1010000X) and B0h (1011000X) are the Serial ID addresses for channel 1 and channel 2, respectively. A2h (1010001X) and B2h (1011001X) are the Digital Diagnostic addresses for channel 1 and channel 2.

9. 引脚定义(Pin Descriptions)

CSFP-B4312-20Dxx 引脚图

CSFP-B4312-20Dxx 1.25G CSFP BIDI Transceiver V3.06 引脚图(image2)— 20 引脚 CSFP 引脚分配(Ch1 + Ch2 双通道)
引脚号(Pin) 信号名(Signal Name) 描述(Description) Plug Seq. 说明(Notes)
1 VeeT Transmitter Ground (Common with Receiver Ground) 1
2 TX Fault Transmitter Fault 3
3 TX1_Disable Transmitter Disable of Ch1; Turns off transmitter laser output of Ch1 3
4 MOD_DEF(2) 2-wire Serial Interface Data Line (SDA) 3
5 MOD_DEF(1) 2-wire Serial Interface Clock Line (SCL) 3
6 TD2- Inverted Transmit Data Input of Ch2 3
7 TD2+ Transmit Data Input of Ch2 3
8 LOS1 Loss of signal for Ch1 3
9 RD2+ Received Data Output of Ch2 3
10 RD2- Inverted Received Data Output of Ch2 3
11 VeeT Transmitter Ground 1
12 RD1- Inverted Received Data Output of Ch1 3
13 RD1+ Received Data Output of Ch1 3
14 LOS2 Loss of signal for Ch2 3
15 VccR Receiver Power Supply 2
16 VccT Transmitter Power Supply 2
17 Tx2_Disable Transmitter Disable of Ch2; Turns off transmitter laser output of Ch2 3
18 TD1+ Transmit Data Input of Ch1 3
19 TD1- Inverted Transmit Data Input of Ch1 3
20 VeeT Transmitter Ground 1
💡 Note: TX_Fault is internally OR output for TX fault conditions in either Channel 1 or Channel 2. In order to determine which channel is at fault, the Host can read the internal memory bits for.

10. 推荐接口电路(Recommended Interface Circuit)

CSFP-B4312-20Dxx 推荐接口电路

CSFP-B4312-20Dxx 1.25G CSFP BIDI Transceiver V3.06 推荐接口电路(image4)— Host Board 接口电路 + Ch1/Ch2 双通道信号路径

11. 机械尺寸(Mechanical Dimensions)

CSFP-B4312-20Dxx 机械尺寸

CSFP-B4312-20Dxx 1.25G CSFP BIDI Transceiver V3.06 机械尺寸(image3)— CSFP 封装尺寸 + Pin-out of Connector Block on Host Board

12. 订货信息(Ordering Information)

型号(Part Number) 产品描述(Product Description)
CSFP-B4312-20D 1490T/1310R 1.25Gbps LC 20km 0°C~+70°C with DDM
CSFP-B4312-20DI 1490T/1310R 1.25Gbps LC 20km -40°C~+85°C with DDM

13. 典型应用场景(Typical Applications)

🔌 BIDI 单纤双向 + CSFP 双通道高密度 4 大应用

Gigabit Ethernet — 千兆以太网光链路
Fibre Channel — 光纤通道链路
FTTx + FTTH — 接入网光通信
单纤双向高密度 — 节省 50% 光纤 + 1 SFP = 2 BIDI 通道
电信机房 — 1490/1310 配对使用
电信级 OLT/ONU — CSFP 紧凑型 SFP 双向
企业级单纤双向链路 — 节省光纤资源
工业级单纤双向 — 工业级型号(CSFP-B4312-20DI)

🌐 F-tone Networks 北亿纤通 — Company Information

Company Name(公司名):北亿纤通 | F-toneNetworks

Region(地区):China Sichuan Tianfu New Area(中国四川天府新区)

Service Area(服务区域):Global(全球)

Tel(企业电话):028-85255257

Fax(企业传真):028-85977702

Mobile(企业手机):19081343401

Site:https://www.f-tone.com

HR(人事部):hr@f-tone.com

Sales(市场部):sales@f-tone.com

Support(技术支持):support@f-tone.com

本产品为【CSFP-B4312-20Dxx 1.25G BIDI 20km 双通道 CSFP 光模块 V3.06】产品线。详细信息请联系我们的销售人员,谢谢!

Important Notice 重要通知

Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.

The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.